C-311

Techincal specifications

System:

  • Fully automated,random access analyzer for clinical Chemistry, Electrolytes & Homogeneous Immunoassays(HIA).

Test throughput:

  • Up to 450 tests/hr.

Reagent concept:                     

  • Barcoded cobas c reagent packs with convenient packaging & ready –to –use reagents.

Onboard reagent capacity:

  • Up to 45 assays (42 cooled cassette slots + channels for ISE).

Programmable parameters:

  • Up to 117 photometric, 3 Ise tests, 8 calculated parameters & 3 serum indices.

Sample types:

 

  • Serum, Plasma, Urine, CSF & Whole Blood.

Onboard sample capacity:

  • 108 positions with continuous access & STAT interrupt capability.

Sample container types:           

  • Primary tubes:   5-10ml (16x 100, 16x75, 13x100, 13x75 mm)
  • Sample cup   :     2.5 ml
  • Micro cup      :     1.5 ml
  • Cup on tube

Sample volume:                       

  • to 35 µl in 0.1 µl steps.

Sample clot detection:             

  • Yes

Minimum sample volume:        

  • Primary tubes:   700 µl
  • Sample cup   :   100 µl
  • Micro cup      :     50 µl

Sample barcode types:             

  • Code 128, codabar (NW 7), Interleaved 2 of 5, code 39.

System interfaces:                    

  • Touchscreen PC, RS 232 serial interface, bi-directional.
  • Cobas link (TeleService and auto download).

 

 

Sample database                    

 

  • 10,000 routine/STAT samples.

 

Test methods:              

 

  • 1 point, 1point+ prozone check, 2 point, 2 point kinetic, 2 point + prozone check,3 point, 1 point + kinetics, rate a, rate a + serum index, rate a with blank, Rate B.

 

Calibration methods:                

 

  • Linear, non-linear multi-points, 2 point calibration, K-factor, up to 100 calibrators pre-programmable, storage of up to 180 curves; Preventive calibration of stand – by cassettes.

 

QC methods:                

  • Real-time, individual & cumulative QC; Auto QC; Up to 100 different controls pre-pro-grammable, Preventive QC after calibration of stand-by cassettes.

Rerun/repeat/reflex:                  

  • Automatic rerun/manual reruns, repeats & automatic reflex supported.

Electrical requirements:           

  • Power requirements:230/400 Volts AC 3/N/PE, 110 Volts AC 1.5 kVA.
  •  Frequency             : 50Hz or 60hz +/- 0.5%.

Water/waste requirements:

  • Water quality        :Bacteria free, de-ionised water supply    resistnce of 1.0 µS/cm max.
  • Water consumption: Up to 12 l/hr during operation.
  • Water Pressure     : 0.5- 3.5 kg/cm3  (49- 343 KPa).
  • Water temperature :15 to 30®C.
  • Biohazards waste  : Separate container located in the system.
  • Wall drain for waste:  100  mm above the floor.

Regulatory compliance:           

  • GS,CE, UL, C-UL compliant.

Operating conditions:              

  • Ambient temperature/humidity: 15 to 32®C/30 to 85% (RH, without condensation)

 ·